Hot water storage calorifiers - 2022

ELECTRIC HEATING KIT: In the column ‘Recommended Pairings’, you will find the recommended capacity/power couplings for stored production. MODELS: RECOMMENDED PAIRINGS VOLTAGE TO BE ADJUSTED ON THE FLANGE REFERENCES Opening only without kit 750 to 3000L - Included in flange version 5kW sheathed heating element kit 500L 3-phase 230/400V 3~ 029 405 10kW sheathed heating element kit 750 to 1000L 3-phase 230/400V 3~ 029 406 15kW sheathed heating element kit 750 to 1500L 3-phase 230/400V 3~ 029 407 25kW sheathed heating element kit 1500 to 3000L 3-phase 230/400V 3~ 029 408 30kW sheathed heating element kit 1500 to 3000L 3-phase 400V 3~ 029 419 Provide a contactor relay and a safety valve (not supplied). TECHNICAL CHARACTERISTICS AND PERFORMANCES CORHYDRO MODELS GENERAL CHARACTERISTICS: 500 750 1000 1000 TB 1500 1500 TB 2000 2500 2500 TB 3000 3000 TB Usable capacity (L) 517 768 1022 1020 1425 1552 2077 2512 2521 3025 2904 Min. tank width 680 795 795 1015 1015 1265 1265 1265 1515 1265 1515 Tilting dimension(1) 180 1960 2480 1730 2270 1720 2180 2530 1970 2950 2180 Min. height of installation area 2100 2135 2660 1890 2415 1895 2330 2690 2106 3115 2326 Min. dimension for placing the anode (mm) with spacers 2350 2535 3210 2440 3165 2645 2680 3090 2506 3465 2576 Empty tank weight (kg) 82 122 155 185 234 290 360 415 470 478 515 Heat loss(2) Ua (W/K) Flexible M1 1.472 1.852 2.250 2.306 2.685 2.991 3.389 3.815 4.120 4.324 4.444 Steel M0 1.311 1.646 1.997 2.046 2.381 2.651 3.003 3.379 3.648 3.828 3.935 (1) Spacers not mounted. (2) Storage at 65°C - Room temperature at 20°C. Values according to RT2012. DIMENSIONAL SPECIFICATIONS (IN MM) CORHYDRO MODELS VALUE REFERENCES 500 750 1000 1000 TB 1500 1500 TB 2000 2500 2500 TB 3000 3000 TB Tank diameter Ø 650 790 790 1000 1000 1250 1250 1250 1500 1250 1500 Overall height without spacers HT 1950 1935 2460 1690 2215 1695 2130 2490 1906 2915 2126 Height with spacers H – 1985 2510 1740 2265 1745 2180 2540 1956 2965 2176 Lower connection A 250 200 200 320 320 320 320 320 320 320 320 Upper connection B 950 937 1200 815 1077 818 1036 1216 923 1428 1033 Height of the opening C1 470 450 450 525 525 591 591 591 658 591 658 Cold water inlet D 250 200 200 320 320 320 320 320 320 320 320 Return loop E 812 778 988 683 893 690 864 1007 778 1179 866 Height under drain F 110 60 Sensor connection 1 1/2” connection Thermometer connection 2 F 15/21 Exchanger connection 3 M 40/49 M 50/60 Cold water (CW) / hot water (HW) / return loop (RL) 4 M 40/49 M 50/60 Drain 5 F33/42 Corhydro B H C1 A 0 HT E RL HW CW D F 0 50 Ø tank 130 130 100 100 100 90° 45° 45° 45° 45° Front view With DN 112 flange opening Top view 1 4 4 3 5 4 2 3 1 7

RkJQdWJsaXNoZXIy NTAwMTk1